Home Page Forums Cymatic Audio Forum Suggestion Box uTrack24 suggestions & feature requests “send to monitor” button for each track in mixer view

Viewing 8 posts - 1 through 8 (of 8 total)
  • Author
    Posts
  • #28666
    Marcus
    Participant

    Hi!

    I’d like to see this feature mentioned above.
    my problem:
    I have several playback stems that will played back using the mixer to be able to alter volume settings and mite stuff when we play with more live instruments.
    the click and cues go out to 23 and 24 and obviously should not go out on the main bus.
    I also need to have my individual outputs on post fader to be able to set click volumes depending on different drummer’s in ear amps.

    so it would be great to be able to explicitly exclude tracks from going out to monitor out while still being post-fader on its own out.

    my workaround so far is using phase inverted click files that cancel out in mixer. This works but is not very elegant 🙂

    Ciao Marcus

    #28669
    Laszlo
    Keymaster

    Hi Marcus,

    The uTrack24 has an internal mixer where you can do the following things:

  • Mute and solo tracks

  • Set volume on each track

  • Pre/Post fader option in the uTrack24 menu will set the DB25 outputs.

    If you set the outputs to post fader mode all the mixer settings (level, mute, solo) will applied on the DB25 outputs.
    In Pre fader mode the mixer settings will be applied only on the MAIN out 1-2 and headphones output.
    You can set the mixer settings by per-configuring the song in uTool, or on the fly by using uRemote or using the monitor mixer in the uTrack24 menu.

#28673
Marcus
Participant

Hi!

Thanks, Yeah, I Know, but that doesn’t fix my problem entirely.
I have the situation:
1. I want to be able to alter the level of out23-24 via the mixer for different click headphone amps, so settings NEEDS to be post-fader here.
2. I want everything else to be mixed and to go out MAIN OUT, post fader obviously, EXCEPT Track 23-24.

-> so I’d like to be able to exclude certain tracks from being routed to MAIN out, but still have the fader leveling the direct out.

#28674
Laszlo
Keymaster

Now it is clear, unfortunately that’s not possible on uTrack24.

#28675
Marcus
Participant

maybe that would be possible to include in a future FW update?
– > a button on every channel “send to main out” that can be deactivated if needed.
or:
make the mute button on the channels not muting their direct out, only the mainmix feed.
that way one can decide wether or not post fader audio goes to main by either using the mute button (=direct out still working) or putting the fader to -inf (direct out off)

#28676
Laszlo
Keymaster

Yup, fully understand what you mean. Unfortunately to do this the uTrack24 need to have one more mixer inside. Unfortunately the uTrack24 has not enough free CPU cycle to do that, for this reason we cannot implement your request

#28677
Marcus
Participant

ah ok!
the phase-inversion trick does work well so far, so it’s not too much of a problem for me.
all in all it’s a great device!
thanks for your quick responses!!

Ciao Marcus

#28678
Laszlo
Keymaster

Thank you!

Glad to hear you are happy with the device.

Viewing 8 posts - 1 through 8 (of 8 total)
  • You must be logged in to reply to this topic.